Influencia del número mínimo de partículas analizadas en el ensayo petrográfico de arenas naturales sobre el resultado final
| cic.institucionOrigen | Centro de Geología Aplicada, Agua y Medio Ambiente | es |
| cic.isFulltext | true | es |
| cic.isPeerReviewed | true | es |
| cic.lugarDesarrollo | Consejo Nacional de Investigaciones Científicas y Técnicas | es |
| cic.lugarDesarrollo | Universidad Nacional de Córdoba | es |
| cic.lugarDesarrollo | Universidad Nacional del Sur | es |
| cic.parentType | Articulo | |
| cic.version | info:eu-repo/semantics/publishedVersion | es |
| dc.date.accessioned | 2019-04-09T17:40:13Z | |
| dc.date.available | 2019-04-09T17:40:13Z | |
| dc.identifier.uri | https://digital.cic.gba.gob.ar/handle/11746/9196 | |
| dc.title | Influencia del número mínimo de partículas analizadas en el ensayo petrográfico de arenas naturales sobre el resultado final | es |
| dc.type | Artículo | es |
| dcterms.abstract | According to the IRAM 1649 (2008) standard, to perform the petrographic test over aggregate for concrete (gravéis, sands or crushed rock) a mínimum of 500 particles must be identified and studied in the material retained in each fraction, to obtain reliable results (in the versión of 1968 the limit was 300 particles). In addition, for precise determinations of small amount, a larger number of particles should be studied. On the other hand, the IRAM 1512 standard indícate the máximum contení of potentially reactive materials allowed, ranging between 5% for highly strained, microcracked or microcrystalline quartz (< 62 pm) and 0.5 % for opal. Given that the mínimum number of particles to count demanded in the international standards is variable (above and below 500), and that is necessary to establish the mínimum limits to determine with certainty the presence of potentially reactive materials in low proportions (up to 0.5 %); a statistical study was carried out. In turn, the valué proposed in the active IRAM 1649 was evaluated. For this reason, and with the objective of avoiding the operator’s error in the identification of some mineral or rock, beads in sizes ranging between N° 18 (< 1 mm) and N° 30 (>0.59mm) were used. A total of 1250 particles of 8 different colors in percentages ranging from 52 % to 0.4 % were taken, and successive and random quartering were used. From the results obtained, it is suggested to re-establish the mínimum limit of 300 particles, because the low standard deviation valúes obtained (lower with successive quartering) and because it was possible to identify all kind of particles present in the sample. | en |
| dcterms.creator.author | Locati, Francisco | es |
| dcterms.creator.author | Lescano, Leticia | es |
| dcterms.creator.author | Marfil, Silvina Andrea | es |
| dcterms.creator.author | Maiza, Pedro Jose | es |
| dcterms.extent | p. 21-26 | es |
| dcterms.isPartOf.issue | no. 56 | es |
| dcterms.isPartOf.series | Revista de la Asociación Argentina de Tecnología del Hormigón | es |
| dcterms.issued | 2017-06-02 | |
| dcterms.language | Español | es |
| dcterms.license | Attribution-NonCommercial-ShareAlike 4.0 International (BY-NC-SA 4.0) | es |
| dcterms.publisher | Asociación Argentina de Tecnología del Hormigón | es |
| dcterms.subject | sand | en |
| dcterms.subject | petrographic method | en |
| dcterms.subject | number of particles | en |
| dcterms.subject | AAR | en |
| dcterms.subject.materia | Geología | es |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Influencia del número mínimo de partículas.pdf-PDFA.pdf
- Size:
- 613.66 KB
- Format:
- Adobe Portable Document Format
- Description:
- Documento completo