<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Influencia del número mínimo de partículas analizadas en el ensayo petrográfico de arenas naturales sobre el resultado final

cic.institucionOrigenCentro de Geología Aplicada, Agua y Medio Ambientees
cic.isFulltexttruees
cic.isPeerReviewedtruees
cic.lugarDesarrolloConsejo Nacional de Investigaciones Científicas y Técnicases
cic.lugarDesarrolloUniversidad Nacional de Córdobaes
cic.lugarDesarrolloUniversidad Nacional del Sures
cic.parentTypeArticulo
cic.versioninfo:eu-repo/semantics/publishedVersiones
dc.date.accessioned2019-04-09T17:40:13Z
dc.date.available2019-04-09T17:40:13Z
dc.identifier.urihttps://digital.cic.gba.gob.ar/handle/11746/9196
dc.titleInfluencia del número mínimo de partículas analizadas en el ensayo petrográfico de arenas naturales sobre el resultado finales
dc.typeArtículoes
dcterms.abstractAccording to the IRAM 1649 (2008) standard, to perform the petrographic test over aggregate for concrete (gravéis, sands or crushed rock) a mínimum of 500 particles must be identified and studied in the material retained in each fraction, to obtain reliable results (in the versión of 1968 the limit was 300 particles). In addition, for precise determinations of small amount, a larger number of particles should be studied. On the other hand, the IRAM 1512 standard indícate the máximum contení of potentially reactive materials allowed, ranging between 5% for highly strained, microcracked or microcrystalline quartz (&amp;lt; 62 pm) and 0.5 % for opal. Given that the mínimum number of particles to count demanded in the international standards is variable (above and below 500), and that is necessary to establish the mínimum limits to determine with certainty the presence of potentially reactive materials in low proportions (up to 0.5 %); a statistical study was carried out. In turn, the valué proposed in the active IRAM 1649 was evaluated. For this reason, and with the objective of avoiding the operator’s error in the identification of some mineral or rock, beads in sizes ranging between N° 18 (&amp;lt; 1 mm) and N° 30 (&amp;gt;0.59mm) were used. A total of 1250 particles of 8 different colors in percentages ranging from 52 % to 0.4 % were taken, and successive and random quartering were used. From the results obtained, it is suggested to re-establish the mínimum limit of 300 particles, because the low standard deviation valúes obtained (lower with successive quartering) and because it was possible to identify all kind of particles present in the sample.en
dcterms.creator.authorLocati, Franciscoes
dcterms.creator.authorLescano, Leticiaes
dcterms.creator.authorMarfil, Silvina Andreaes
dcterms.creator.authorMaiza, Pedro Josees
dcterms.extentp. 21-26es
dcterms.isPartOf.issueno. 56es
dcterms.isPartOf.seriesRevista de la Asociación Argentina de Tecnología del Hormigónes
dcterms.issued2017-06-02
dcterms.languageEspañoles
dcterms.licenseAttribution-NonCommercial-ShareAlike 4.0 International (BY-NC-SA 4.0)es
dcterms.publisherAsociación Argentina de Tecnología del Hormigónes
dcterms.subjectsanden
dcterms.subjectpetrographic methoden
dcterms.subjectnumber of particlesen
dcterms.subjectAARen
dcterms.subject.materiaGeologíaes

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Influencia del número mínimo de partículas.pdf-PDFA.pdf
Size:
613.66 KB
Format:
Adobe Portable Document Format
Description:
Documento completo