Modelo numérico de flujo subterráneo para una cuenca endorréica en ambiente árido: Salar de Pipanaco (Catamarca, Argentina)
Abstract
A regional groundwater flow model has been developed for the Salar de Pipanaco (Catamarca, NE Argentina). The model was made under steady and transient states, the last one for the period 1995-2015, based on two hypotheses: a) the evapotranspiration as the main discharge mechanism in the system, and b) an additional preferential discharge through regional fault zones. In both cases, the aquifer has been divided into 14 permeability areas, 4 vegetation areas with different evaporative capacity, and 8 pumping areas. The results indicate that the calibrated hydraulic conductivities ranges from 1.7 to 55.9 m/d, and those ones are consistent with the lithology and local groundwater pumping tests. The differences between measured and calculated piezometric levels are less than 5 m. The water budget shows an overdrawn aquifer unable to retain its storage. The two previous hypothesis are likely, and probably both mechanisms occur in an alternately way.