Corrosión localizada del acero inoxidable austenítico en medio de cultivo celular y evaluación de la citotoxicidad de los iones liberados

cic.institucionOrigenLaboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológicaes
cic.isFulltexttruees
cic.isPeerReviewedtruees
cic.lugarDesarrolloLaboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológicaes
cic.lugarDesarrolloInstituto Multidisciplinario de Biología Celulares
cic.lugarDesarrolloCentro de Investigación y Desarrollo en Tecnología de Pinturases
cic.versioninfo:eu-repo/semantics/publishedVersiones
dc.date.accessioned2022-05-03T16:37:54Z
dc.date.available2022-05-03T16:37:54Z
dc.identifier.urihttps://digital.cic.gba.gob.ar/handle/11746/11568
dc.titleCorrosión localizada del acero inoxidable austenítico en medio de cultivo celular y evaluación de la citotoxicidad de los iones liberadoses
dc.typeArtículoes
dcterms.abstractEl acero inoxidable austenítico ASTM F745 ha sido sometido a corrosión localizada en medio de cultivo celular y solución acuosa de NaCl, cuyas concentraciones de cloruro fueron 4413,2 mg L-1 y 5423,1 mg L-1, respectivamente. Se ha observado que la susceptibilidad a la corrosión localizada fue menor en el medio de cultivo debido a su menor contenido de cloruros. El Fe fue el metal más liberado en ambos medios durante el proceso de corrosión. Las concentraciones fueron 0,570 mg L-1 en la solución acuosa de NaCl y 0,480 mg L-1 en el medio de cultivo. Las concentraciones de Cr y Mo fueron similares en ambos medios, habiendo sido 0,040 mg L-1 y 0,010 mg L-1, respectivamente, mientras que Ni solo se detectó en la solución acuosa de NaCl, 0,100 mg L-1. Estas concentraciones de iones liberados no provocaron efectos citotóxicos en células similares a osteoblastos.es
dcterms.abstractAustenitic stainless steel ASTM F745 has been submitted to localized corrosion in cell culture medium and NaCl aqueous solution, whose chloride concentrations were 4413,2 mg L-1 and 5423,1 mg L-1, respectively. It has been observed that the susceptibility to localized corrosion was lower in the culture medium due to its lower chloride content. Fe was the most released metal in both media during the corrosion process. The concentrations were 0,570 mg L-1 in the NaCl aqueous solution and 0,480 mg L-1 in the culture medium. The concentrations of Cr and Mo released were similar in both media, having been 0,040 mg L-1 and 0,010 mg L-1, respectively, while Ni was only detected in the NaCl aqueous solution, 0,100 mg L-1. These concentrations of ions released did not cause cytotoxic effects in osteoblast-like cells.en
dcterms.alternativeLocalized corrosion of austenitic stainless steel in cell culture medium and evaluation of the cytotoxicity of the released ionsen
dcterms.creator.authorParisi, Julieta Marciaes
dcterms.creator.authorCastrogiovanni, Danieles
dcterms.creator.authorGrau, Jorge Enriquees
dcterms.creator.authorGregorutti, Ricardo Walteres
dcterms.creator.authorElsner, Cecilia Inéses
dcterms.extent9-18es
dcterms.identifier.otherISSN 2250-5989es
dcterms.isPartOf.issueno. 11es
dcterms.isPartOf.seriesRevista Ciencia y Tecnología de los Materialeses
dcterms.issued2021
dcterms.languageEspañoles
dcterms.licenseAttribution 4.0 International (BY 4.0)es
dcterms.subjectCorrosión localizadaes
dcterms.subjectLiberación de ioneses
dcterms.subjectCitotoxicidades
dcterms.subjectAcero inoxidable austeníticoes
dcterms.subjectLocalized corrosionen
dcterms.subjectIon releaseen
dcterms.subjectCytotoxicityen
dcterms.subjectAustenitic stainless steelen
dcterms.subject.materiaIngeniería de los Materialeses

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
1-Corosión localizada.pdf-PDFA.pdf
Tamaño:
1.24 MB
Formato:
Adobe Portable Document Format
Descripción:
Documento completo