<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Causas y prevencion del deterioro de la madera de torres de enfriamiento de agua

cic.isFulltexttruees
cic.isPeerReviewedtruees
cic.lugarDesarrolloLaboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica es
cic.parentTypeArticulo
cic.versioninfo:eu-repo/semantics/submittedVersiones
dc.date.accessioned2015-09-03T12:22:23Z
dc.date.available2015-09-03T12:22:23Z
dc.identifier.urihttps://digital.cic.gba.gob.ar/handle/11746/1072
dc.titleCausas y prevencion del deterioro de la madera de torres de enfriamiento de aguaes
dc.typeArtículoes
dcterms.abstractThe cooling of running water is carried out .in most industrial plants with the use of cooling towers. The wood is the material most generally used in the construction of these towers,, due to its durability, light weight, availability and cost. This demand a study of the requeriments for its use, of the agents that attack same and, of the methods for prevention.en
dcterms.alternativeWater cooling towers: causes of deterioration of the wood and preventive methodsen
dcterms.creator.authorBorlando, Luises
dcterms.extent12 p.es
dcterms.isPartOf.issueSerie II, 1970, nº 3es
dcterms.isPartOf.seriesAnales LEMITes
dcterms.issued1970
dcterms.languageEspañoles
dcterms.licenseAttribution 4.0 International (BY 4.0)es
dcterms.publisherLaboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica (LEMIT)es
dcterms.subjectindustrial plantsen
dcterms.subjectcooling towersen
dcterms.subjectuse requerimentsen
dcterms.subjectdestructive agentsen
dcterms.subjectwooden